Review




Structured Review

EIAab Inc microscope slides beijing
(A) Immunofluorescence on Hepa1-6 cells for detection of ANAs. The images are representative staining patterns using ×200 diluted sera of 12-month-old WT and TAM −/− mice (n = 5 mice each genotype). Scale bar = 40 µm. (B) The sera were diluted in series. Each circle indicates the maximum dilution of sera from individual mice, in which ANAs can be detectable. (C) Measurement of anti-actin autoantibody component of SMA using ELISA. Each circle indicates unit of anti-actin autoantibodies in sera of individual mice. (D) Titer of SMA. The <t>microscope</t> slides (Rat stomach) were stained using sera at the indicated dilutions. (E) Plasma IgG. The plasma were collected from 12-month-old mice. IgG levels were measured using ELISA.
Microscope Slides Beijing, supplied by EIAab Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/microscope+slides+beijing/pmc03684578-71-10-13?v=EIAab+Inc
Average 90 stars, based on 1 article reviews
microscope slides beijing - by Bioz Stars, 2026-07
90/100 stars

Images

1) Product Images from "Development of a Spontaneous Liver Disease Resembling Autoimmune Hepatitis in Mice Lacking Tyro3, Axl and Mer Receptor Tyrosine Kinases"

Article Title: Development of a Spontaneous Liver Disease Resembling Autoimmune Hepatitis in Mice Lacking Tyro3, Axl and Mer Receptor Tyrosine Kinases

Journal: PLoS ONE

doi: 10.1371/journal.pone.0066604

(A) Immunofluorescence on Hepa1-6 cells for detection of ANAs. The images are representative staining patterns using ×200 diluted sera of 12-month-old WT and TAM −/− mice (n = 5 mice each genotype). Scale bar = 40 µm. (B) The sera were diluted in series. Each circle indicates the maximum dilution of sera from individual mice, in which ANAs can be detectable. (C) Measurement of anti-actin autoantibody component of SMA using ELISA. Each circle indicates unit of anti-actin autoantibodies in sera of individual mice. (D) Titer of SMA. The microscope slides (Rat stomach) were stained using sera at the indicated dilutions. (E) Plasma IgG. The plasma were collected from 12-month-old mice. IgG levels were measured using ELISA.
Figure Legend Snippet: (A) Immunofluorescence on Hepa1-6 cells for detection of ANAs. The images are representative staining patterns using ×200 diluted sera of 12-month-old WT and TAM −/− mice (n = 5 mice each genotype). Scale bar = 40 µm. (B) The sera were diluted in series. Each circle indicates the maximum dilution of sera from individual mice, in which ANAs can be detectable. (C) Measurement of anti-actin autoantibody component of SMA using ELISA. Each circle indicates unit of anti-actin autoantibodies in sera of individual mice. (D) Titer of SMA. The microscope slides (Rat stomach) were stained using sera at the indicated dilutions. (E) Plasma IgG. The plasma were collected from 12-month-old mice. IgG levels were measured using ELISA.

Techniques Used: Immunofluorescence, Staining, Enzyme-linked Immunosorbent Assay, Microscopy, Clinical Proteomics



Similar Products

90
EIAab Inc microscope slides beijing
(A) Immunofluorescence on Hepa1-6 cells for detection of ANAs. The images are representative staining patterns using ×200 diluted sera of 12-month-old WT and TAM −/− mice (n = 5 mice each genotype). Scale bar = 40 µm. (B) The sera were diluted in series. Each circle indicates the maximum dilution of sera from individual mice, in which ANAs can be detectable. (C) Measurement of anti-actin autoantibody component of SMA using ELISA. Each circle indicates unit of anti-actin autoantibodies in sera of individual mice. (D) Titer of SMA. The <t>microscope</t> slides (Rat stomach) were stained using sera at the indicated dilutions. (E) Plasma IgG. The plasma were collected from 12-month-old mice. IgG levels were measured using ELISA.
Microscope Slides Beijing, supplied by EIAab Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/microscope+slides+beijing/pmc03684578-71-10-13?v=EIAab+Inc
Average 90 stars, based on 1 article reviews
microscope slides beijing - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

Image Search Results


(A) Immunofluorescence on Hepa1-6 cells for detection of ANAs. The images are representative staining patterns using ×200 diluted sera of 12-month-old WT and TAM −/− mice (n = 5 mice each genotype). Scale bar = 40 µm. (B) The sera were diluted in series. Each circle indicates the maximum dilution of sera from individual mice, in which ANAs can be detectable. (C) Measurement of anti-actin autoantibody component of SMA using ELISA. Each circle indicates unit of anti-actin autoantibodies in sera of individual mice. (D) Titer of SMA. The microscope slides (Rat stomach) were stained using sera at the indicated dilutions. (E) Plasma IgG. The plasma were collected from 12-month-old mice. IgG levels were measured using ELISA.

Journal: PLoS ONE

Article Title: Development of a Spontaneous Liver Disease Resembling Autoimmune Hepatitis in Mice Lacking Tyro3, Axl and Mer Receptor Tyrosine Kinases

doi: 10.1371/journal.pone.0066604

Figure Lengend Snippet: (A) Immunofluorescence on Hepa1-6 cells for detection of ANAs. The images are representative staining patterns using ×200 diluted sera of 12-month-old WT and TAM −/− mice (n = 5 mice each genotype). Scale bar = 40 µm. (B) The sera were diluted in series. Each circle indicates the maximum dilution of sera from individual mice, in which ANAs can be detectable. (C) Measurement of anti-actin autoantibody component of SMA using ELISA. Each circle indicates unit of anti-actin autoantibodies in sera of individual mice. (D) Titer of SMA. The microscope slides (Rat stomach) were stained using sera at the indicated dilutions. (E) Plasma IgG. The plasma were collected from 12-month-old mice. IgG levels were measured using ELISA.

Article Snippet: The titers of serum autoantibodies against SMA were detected using microscope slides (Beijing EIAab Science Co. Beijing, China) according to manufacturer′s instructions.

Techniques: Immunofluorescence, Staining, Enzyme-linked Immunosorbent Assay, Microscopy, Clinical Proteomics